In short
- C3-100: 1 door, 2 Wiegand readers, 1 lock relay + 1 auxiliary. C3-200: 2 doors, 4 Wiegand readers, 2 lock relays + 2 auxiliary (ZKTeco C3 Plus specifications).
- Gymza drives one lock relay per door and never the auxiliary relay: one door = one controlled direction.
- Entry controlled, exit free → C3-100. Entry and exit controlled, or two entrances → C3-200.
- Both are driven by the same Gymza adapter: implemented, validated against a simulator, not yet on a physical panel.
The two models compared
| C3-100 Plus | C3-200 Plus | |
|---|---|---|
| Doors (access points) | 1 | 2 |
| Wiegand readers (26/34/66-bit) | 2 | 4 |
| RS-485 / OSDP readers | 2 | 4 |
| Form C relays | 1 lock + 1 auxiliary | 2 locks + 2 auxiliary |
| Exit button / door sensor / auxiliary inputs | 1 / 1 / 1 | 2 / 2 / 2 |
| Network | TCP/IP, RS-485 | TCP/IP, RS-485 |
| Capacity | 100,000 cards, 500,000 transactions | 100,000 cards, 500,000 transactions |
| Power | 9.6–14.4 V DC | 9.6–14.4 V DC |
| Size | 175 × 99 × 19.3 mm | 175 × 99 × 19.3 mm |
Older generations (C3-100, C3-100 Pro, C3-200 Pro) exist and their figures differ; check the label and the specifications of the exact panel you are offered. ZKTeco names the two-door model “C3-200 Pro Plus” on its TS2000 Plus page, where it is the recommended controller.
Why the number of doors decides it
A tripod turnstile has a control input for each direction. When Gymza grants an entry, it asks the controller to pulse the lock relay of the door bound to that entrance; that contact releases the entry direction. To release the exit separately, Gymza needs a second door, that is a second lock relay.
A C3-100 has two Wiegand reader ports for its single door, so a reader can sit on each side. But both readers would then open the same relay, so the panel cannot release the right direction. Gymza does not use the auxiliary relay for this.
| Set-up | Controller | In Gymza |
|---|---|---|
| One turnstile, entry controlled, exit free-wheeling | C3-100 (or C3-200 with one door used) | One device: door 1, In |
| One turnstile, entry and exit controlled | C3-200 | Two devices, same IP: door 1 In, door 2 Out |
| Two separate entrances (e.g. main door and studio) | C3-200 | Two devices, each bound to its entrance |
| Three or four doors | C3-400 (not covered here) | One device per door (doors 1 to 4) |
Do you need to control the exit?
- Free exit is the simplest: members leave by pushing the arm. Gymza still applies anti-passback and daily limits on entry.
- Controlled exit tells Gymza who left. Exits are always granted and never consume a visit; they make “currently inside” and anti-passback accurate.
- Whatever you choose, the emergency route must not depend on software: a mechanical release that cuts the lock power is required.
What Gymza does with either model
Gymza leaves the panel holding none of its cards. Every badge is an unregistered card to the panel; Gymza reads its real-time log over TCP 4370, decides, and pulses the relay. It never writes the panel’s user table, clock or configuration. With either model, a PC that is off means a door that does not open: put the PC and the controller on the same UPS.
Device pages: C3-100, C3-200. Wiring a turnstile: dry-contact relays and connecting a turnstile.
Sources
Facts about other manufacturers’ products come from these documents. Gymza’s capabilities are checked in the application.
- C3 Plus Series, product page (opens in a new tab) · ZKTeco · accessed
- TS2000 Plus Series, product page (opens in a new tab) · ZKTeco · accessed