- A dry contact is a switch with no voltage of its own: it only connects two terminals of the device it controls.
- Controllers such as the ZKTeco C3 have Form C relays: COM, NO (normally open) and NC (normally closed). A turnstile entry input is usually wired to NO/COM.
- In Gymza, the controller times the pulse (4 s by default), not the PC, so a crash or update never leaves a turnstile stuck open.
- Emergency release is wired, not programmed: on power loss, the arms must drop or the lock must open, whatever the software does.
What “dry contact” means
A relay is a switch moved by an electromagnet. When its contacts are dry (or “voltage-free”), the relay supplies no current to what it controls: it simply joins two wires of the other device, like a push button would. The turnstile’s own board supplies the small current and sees “contact closed = release one passage”.
That is why a controller can drive equipment of almost any brand: as long as the turnstile, gate or door strike has an input that expects a contact closure, the controller does not need to know anything else about it.
COM, NO and NC
| Terminal | At rest | When the relay is activated | Typical use |
|---|---|---|---|
| COM (common) | Not applicable | Not applicable | Always wired; the moving part of the switch |
| NO (normally open) | Open | Closed to COM | Turnstile “release” input, door strike that opens when powered |
| NC (normally closed) | Closed to COM | Open | Magnetic lock that must lose power to open |
ZKTeco’s C3 Plus panels list Form C relays: one lock relay per door, plus auxiliary relays. Gymza’s turnstile guide wires the turnstile’s entry-direction input to LOCK1 NO/COM of a C3-200, and the exit to LOCK2.
Who does what, from badge to arm
- 1BadgeThe member shows a card, key fob or wristband.
- 2ReaderIt reads the number and sends it to the controller, usually over Wiegand.
- 3ControllerIt passes the read to the PC over the network cable.
- 4GymzaMembership, hours, unpaid balance, anti-passback: the software decides.
- 5RelayThe controller closes the contact for a few seconds.
- 6TurnstileThe arm releases and the entry is recorded.
The software decides (4)
The controller opens (5–6)
- The reader reads the badge and sends the number to the controller (usually Wiegand).
- Gymza checks membership, hours, unpaid balance and anti-passback.
- The controller closes its relay for the configured time: the controller times it, not the PC.
- The turnstile sees the contact and releases one passage in that direction.
Fail-safe, fail-secure and the fire alarm
- Fail-safe: the barrier opens when power is lost. A turnstile whose arms drop on power loss, or a maglock on NC. Required on an escape route.
- Fail-secure: the barrier stays locked without power. Acceptable for a storeroom, not for the gym’s way out.
- Fire alarm: ZKTeco’s TS2000 Plus has a voltage-free fire-alarm input that drops the arms. Wire the fire panel there, independently of the software.
- A break-glass or push bar must cut the lock’s power directly. Gymza’s emergency release is a convenience on top, never the safety mechanism.
Wiring mistakes that cause intermittent openings
| Symptom | Likely cause |
|---|---|
| Releases sometimes, not always | No shared ground between controller and turnstile |
| Never releases although the relay clicks | Wired to NC instead of NO, or to the wrong direction input |
| Stays released | Wired to NC on an input that expects NO, or a latched relay after a fire-alarm test |
| Reader loses reads when the arm moves | Reader or controller powered from the turnstile supply |
| Turnstile damaged input | A powered output wired to a dry-contact input: never inject voltage |
Before bolting anything down, use Hardware → Test in Gymza: if the relay clicks and the turnstile does not move, the problem is on the turnstile side; if it does not click, it is the controller’s wiring or power.
Which devices can be driven this way?
Any barrier with a dry-contact control input: tripod turnstiles such as the ZKTeco TS2000 Plus, swing gates, door strikes and magnetic locks. What matters is the controller Gymza talks to: today a ZKTeco C3 (implemented, validation pending) or a controller speaking Gymza’s published Door Link protocol. When a manufacturer does not publish the control input, as for the TS1000 Pro, check the wiring diagram before buying.