In short
- Per ZKTeco: bidirectional as standard, 550 mm lane, 775 × 1100 × 980 mm, 110/220 V AC and 12 V DC, 40 VA running / 10 VA standby, 25 RFID passages a minute, IPX4, MCBF 2 million.
- Arms drop automatically on power loss or on an emergency signal; a voltage-free fire-alarm input is provided.
- ZKTeco recommends the C3-200 Pro Plus; Gymza documents the wiring: entry input on LOCK1 NO/COM, exit on LOCK2, shared ground.
- Status: implemented, validation pending: it depends on Gymza’s C3 adapter, not yet run on a physical panel. Offered in Gymza Custom only.
What works with Gymza
| Function | Status | Evidence or limit |
|---|---|---|
| Entry released by Gymza through a C3-200 | Implemented, validation pending | Implemented: Gymza pulses lock relay 1 (4 s by default), wired to the turnstile’s entry-direction input. Not yet bench-tested with a physical TS2000 Plus. |
| Exit controlled as well | Implemented, validation pending | Implemented: second reader on RD2, LOCK2 to the exit input, a second Gymza device (door 2, Out). Exits are always granted. |
| Direct connection to Gymza | Not supported | Not supported: the turnstile has no interface Gymza talks to; its RS-485 port is not used. It is driven only through the controller. |
Specifications
Manufacturer values are taken from its documentation; values marked “Gymza” come from the application or our tests.
| Specification | Value | Source |
|---|---|---|
| Type | Tripod, single lane, bidirectional as standard | [1] Manufacturer |
| Lane width | 550 mm (barrier 515 mm) | [1] Manufacturer |
| Dimensions (L × W × H) | 775 × 1100 × 980 mm | [1] Manufacturer |
| Material | SUS304 stainless chassis, 1.2 mm | [1] Manufacturer |
| Power supply | 110/220 V AC, 50–60 Hz; 12 V DC | [1] Manufacturer |
| Power consumption | 10 VA standby, 40 VA operation | [1] Manufacturer |
| Throughput | RFID: 25/min; fingerprint: 20/min | [1] Manufacturer |
| Arm drop | Drops automatically on power loss or emergency signal | [1] Manufacturer |
| Fire input | Voltage-free fire-alarm input | [1] Manufacturer |
| Ingress protection | IPX4 | [1] Manufacturer |
| Operating temperature | −20 °C … 70 °C | [1] Manufacturer |
| MCBF | 2 million cycles | [1] Manufacturer |
| Recommended controllers | C3-200 Pro Plus, InBio260 Pro Plus | [1] Manufacturer |
| Wiring documented by Gymza | Entry-direction input wired to the C3-200’s LOCK1 NO/COM, shared ground | [4] Gymza |
| Lifecycle | Marked “EOL” on ZKTeco’s TS Series listing (not on the product page) | [2] Manufacturer |
What the TS2000 Plus is
ZKTeco’s TS2000 Plus page describes a single-lane tripod with a SUS304 stainless chassis (1.2 mm) and a lid in PC, tempered glass and stainless steel. Movement is bidirectional as standard, and each direction’s arm mode is configurable. Under-mount readers can be ZKTeco ProID or KR series (RFID) or FR1200/FR1500S (fingerprint); remote controls and a QR reader are options.
For a gym, two lines of the specification matter most: the arms drop on power loss or an emergency signal, and the fire-alarm input is a voltage-free contact: the safety behaviour does not depend on any software.
How it is driven by Gymza
- 1BadgeThe member shows a card, key fob or wristband.
- 2ReaderIt reads the number and sends it to the controller, usually over Wiegand.
- 3ControllerIt passes the read to the PC over the network cable.
- 4GymzaMembership, hours, unpaid balance, anti-passback: the software decides.
- 5RelayThe controller closes the contact for a few seconds.
- 6TurnstileThe arm releases and the entry is recorded.
The software decides (4)
The controller opens (5–6)
The turnstile itself never talks to Gymza. A Wiegand reader under its lid reads the card; the C3-200 reports it to Gymza over the network; Gymza checks the membership, hours, balance and anti-passback; then asks the C3 to close lock relay 1 for 4 seconds. That contact, wired to the turnstile’s entry-direction input, releases one passage.
| Qty | Item | Role |
|---|---|---|
| 1 | ZKTeco TS2000 Plus | The barrier |
| 1 | ZKTeco C3-200 Pro Plus | Reads the reader, drives the relays, talks to Gymza |
| 1 | Wiegand RFID reader on the entry side | Reads the member’s card |
| 1 | USB RFID reader at reception | Enrols cards |
| 100 | MIFARE 13.56 MHz cards | The members’ credentials |
Installation, in the right order
- Stand the turnstile on a level floor, 5 cm free behind it for the cable gland, not bolted down yet.
- Feed it from its own 12 V supply, not from the controller. Power it with nothing connected and check that the arms drop and re-lock by hand.
- Pull the mains: the arms must fall free. Test the anti-panic drop that way, never by a command.
- Wire the C3-200: entry reader on RD1, LOCK1 NO/COM to the entry-direction input, shared ground, LAN to the gym’s switch.
- Declare the C3 in Gymza, make the two readers agree on the card number, then run the bench test: test pulse, valid card, lapsed card, network cable unplugged.
- Only then bolt the turnstile down. Optionally add the exit: RD2, LOCK2, a second Gymza device (door 2, Out).
Practical use in a gym
- Anti-passback on: the rule that stops one card letting several people in, and a tripod is exactly where it pays.
- Daily limit of one entry, unless the gym sells multi-visit passes.
- Exit free-wheeling (no exit reader) for the simplest set-up; controlled exit when you need to know who is inside.
- A staffed reception next to it for guests, deliveries and members whose membership needs renewing.
Advantages and limits
| In practice | |
|---|---|
| Safety | Arms drop on power loss; voltage-free fire input (manufacturer specification) |
| Throughput | 25 RFID passages a minute per ZKTeco: enough for a gym’s peak hour on one lane |
| Integration | Wiring documented by Gymza; recommended controller is the one Gymza drives |
| PC dependency | With the C3 holding no cards, a PC that is off means a turnstile that does not turn: share a UPS |
| Validation | The C3 adapter has not yet been run on a physical panel |
Troubleshooting
| Symptom | Check |
|---|---|
| No release on Gymza’s Test | Relay click? Yes → turnstile input wiring or direction mode; no → C3 wiring or power |
| Releases intermittently | Shared ground between C3 and turnstile |
| Reader drops reads when the arm moves | Reader powered from the turnstile supply: move it to the C3’s reader supply |
| Wrong member or random numbers | Wiegand cable next to the motor cable |
| Arms do not drop in a power cut | Stop: fix the fail-safe before opening to members |
Frequently asked questions
Does the ZKTeco TS2000 Plus work with Gymza?
It is the turnstile of Gymza’s documented kit, driven through a ZKTeco C3-200. Gymza’s side is implemented but the C3 adapter has not yet been validated on a physical panel, so the kit is offered only in Gymza Custom after a bench test.
What happens to the TS2000 Plus during a power cut?
According to ZKTeco, the arms drop automatically on power loss or on an emergency signal, so the lane is free. Test it by cutting the mains during commissioning.
Can the exit be controlled too?
Yes: add a reader on the exit side, wire it to the C3-200’s second door and add a second device in Gymza (door 2, direction Out). Exits are always granted; they keep anti-passback accurate.
Sources
Documents read for this page, with the date they were read. Gymza evidence is the application and its test records (not public).
- Manufacturer · TS2000 Plus Series, product page (opens in a new tab) · ZKTeco · accessed
- Manufacturer · TS Series, product listing (opens in a new tab) · ZKTeco · accessed
- Manufacturer · TS1000 Plus Series, product page (opens in a new tab) · ZKTeco · accessed
- Gymza · Gymza application: turnstile commissioning guide (INSTALL-TURNSTILE.md) and ZKTeco C3 adapter · Atlaxys Consulting · accessed