In short
- Two doors, 4 Wiegand readers (W26/W34/W66), 2 lock relays + 2 auxiliary, TCP/IP and RS-485 (ZKTeco’s C3 Plus specifications).
- With Gymza, door 1 = entry (In) and door 2 = exit (Out): one Gymza device per door, same IP and port. Exits are always granted and keep anti-passback truthful.
- The panel holds no cards: Gymza decides every passage. A PC that is off means a turnstile that does not turn: share a UPS.
- Status: implemented, validation pending; offered only in a Gymza Custom set-up after a bench test by ATLAXYS.
What works with Gymza
| Function | Status | Evidence or limit |
|---|---|---|
| Connection, model and firmware | Implemented, validation pending | Implemented: TCP 4370 handshake; the device log should show “CONNECTED C3-200 …, 2 door(s)” with the panel’s own model and firmware. |
| Badge reads in real time | Implemented, validation pending | Implemented: every badge is an “unregistered card” to the panel; Gymza reads its real-time log and maps door 1 and door 2 to their entrance. |
| Releasing entry (door 1) | Implemented, validation pending | Implemented: lock relay 1 pulsed for the configured time (4 s by default). Validated byte for byte against a simulator only. |
| Controlled exit (door 2) | Implemented, validation pending | Implemented: a second Gymza device on the same panel, door 2, direction Out. Exits never consume a visit. |
| Opening when the PC is off | Not supported | Not supported with Gymza alone (panel holds no cards). Options: cards loaded with ZKAccess as an independent fallback, or a Door Link controller in hybrid mode. |
| Automatic detection on the local network | Implemented, validation pending | Implemented (Gymza 1.3.5): Gymza finds the controller on the PC’s local network and reads only its model, firmware and serial number, with no password and no relay. Nothing is saved without the administrator; a new address is recognised by the serial number. C3 driver experimental. |
| Fingerprints | Not supported | Not supported: a classic C3 stores and matches no fingerprints, and its protocol has no biometric command. With readers such as the KR901, this hardware works with badges only. For fingerprints: a ZKTeco controller that stores and matches fingerprints itself, enrolled from a ZK8500R USB reader at reception (Gymza 1.4.0, experimental). |
Specifications
Manufacturer values are taken from its documentation; values marked “Gymza” come from the application or our tests.
| Specification | Value | Source |
|---|---|---|
| Doors | 2 | [1] Manufacturer |
| Wiegand readers | 4 (W26 / W34 / W66) | [1] Manufacturer |
| RS-485 readers | 4 (ZKTeco RS-485 / OSDP) | [1] Manufacturer |
| Relays | 2 lock relays + 2 auxiliary (Form C) | [1] Manufacturer |
| Inputs | 2 exit buttons, 2 door sensors, 2 auxiliary inputs | [1] Manufacturer |
| Network | TCP/IP ×1, RS-485 ×1 | [1] Manufacturer |
| Capacity | 100,000 cards, 500,000 transactions | [1] Manufacturer |
| Power supply | 9.6–14.4 V DC | [1] Manufacturer |
| Operating temperature | 0 °C … 45 °C | [1] Manufacturer |
| Dimensions (L × W × H) | 175 × 99 × 19.3 mm | [1] Manufacturer |
| How Gymza uses it | Door 1 = entry (IN), door 2 = exit (OUT), one Gymza device per door | [3] Gymza |
What the C3-200 is
ZKTeco’s C3 Plus series page lists the C3-200 Plus with 2 access points, 4 Wiegand reader ports (26/34/66-bit), 4 RS-485/OSDP readers, Form C relays for 2 locks + 2 auxiliary outputs, two exit-button, two door-sensor and two auxiliary inputs, one TCP/IP and one RS-485 port, capacity for 100,000 cards and 500,000 transactions, a 9.6–14.4 V DC supply and 175 × 99 × 19.3 mm.
How Gymza drives it
- 1BadgeThe member shows a card, key fob or wristband.
- 2ReaderIt reads the number and sends it to the controller, usually over Wiegand.
- 3ControllerIt passes the read to the PC over the network cable.
- 4GymzaMembership, hours, unpaid balance, anti-passback: the software decides.
- 5RelayThe controller closes the contact for a few seconds.
- 6TurnstileThe arm releases and the entry is recorded.
The software decides (4)
The controller opens (5–6)
- A member presents a card at the entry reader (reader port of door 1).
- The C3-200, holding none of Gymza’s cards, logs an “unregistered card, door 1”.
- Gymza reads the log within a fraction of a second and applies the rules: membership, hours, balance, anti-passback, daily limit, visit packs.
- If allowed, Gymza asks the panel to pulse lock relay 1; the turnstile releases one passage in the entry direction, and the customer display greets the member.
- On the way out, a card at the exit reader (door 2) is always granted: relay 2 releases the exit and Gymza records that the member left.
Gymza never writes the panel’s user table, clock or configuration and never restarts it. If the gym must open while the PC is off, the honest options are cards loaded into the panel with ZKAccess as a separate fallback list, or a Door Link controller that holds a whitelist pushed by Gymza.
Wiring a tripod turnstile
| C3-200 terminal | Goes to | Notes |
|---|---|---|
| RD1 D0 / D1 | Entry Wiegand reader, Data0 / Data1 | Reader 1, door 1, entry |
| RD1 +12V / GND | Entry reader power | Check the reader’s own voltage |
| LOCK1 NO / COM | Turnstile entry-direction input | Dry contact, normally open |
| RD2 and LOCK2 | Exit reader and exit-direction input | Only if the exit is controlled |
| GND | Turnstile 0 V | Shared ground, or the pulse is unreliable |
| LAN | The gym’s switch | Same switch as the reception PC |
| 12 V / GND | The C3’s own supply | Not shared with the turnstile motor |
Keep Wiegand runs under 100 m and away from the motor cable: Wiegand has no error checking, so interference becomes wrong numbers rather than missing ones. More detail on relays in dry contact explained.
Commissioning: the bench test comes first
- Give the C3 a fixed IP on the PC’s subnet and check port 4370 from the PC.
- In Gymza: Hardware → Add a device, adapter
zkteco.c3, IP, port 4370, door 1, direction In, the entrance. Leave the password empty unless a communication password was set in ZKAccess, and close ZKAccess or ZKBioSecurity on every PC. The device turns green and its log names the model and firmware. - Make the two readers agree: enrol one card at reception, present it at the turnstile, read the log (“Badge matched … via=…”), then pin Badge number format.
- Test in Hardware: the relay clicks and the turnstile releases. No click means wiring, not software.
- Present a valid card (arm releases, “ACCESS GRANTED”), then a lapsed one (no release; the display only says to see reception).
- Unplug the network cable, present a card (nothing happens, as expected), plug it back: the panel reconnects and its recorded passage appears with its own time.
- Only then bolt the turnstile down, and add a second device (door 2, Out) for the exit.
Settings that matter
- Mode: Online. With a panel holding no cards, that is what is really happening; “Hybrid” would claim something this hardware does not do.
- Unlock duration: 4 s: long enough for one person, short enough that two cannot follow.
- Anti-passback on, a daily entry limit unless you sell multi-visit passes, opening hours with a few minutes of tolerance.
Troubleshooting
| Symptom | Where to look |
|---|---|
| Panel red, “no answer” | Cable, IP, port 4370; is ZKAccess holding the connection? |
| “The panel refused the command” although ZKAccess works | Before Gymza 1.3.6, a panel with no communication password could be refused: update Gymza, close ZKAccess, leave the password empty unless one was set in ZKAccess |
| “Connection closed” although ZKAccess works | Before Gymza 1.3.7, some C3-200 that work without a session never connected: update Gymza, close ZKAccess or ZKBioSecurity on every PC |
| Card read, arm does not move | Hardware → Test. A click means wiring is fine: check the entrance binding |
| Some cards work, others do not | Card format (mixed batches with different UID lengths) |
| Wrong member or drifting numbers | Wiegand interference: reroute the data cable, check the ground |
| Passages appear late, in a batch | Normal after a PC restart: the panel’s own records replayed with their real times |
| Arm releases twice for one badge | Two readers on the same door |
Frequently asked questions
Is the ZKTeco C3-200 compatible with Gymza?
Gymza implements its network protocol, reads badge events and drives both doors. It has been validated against a simulator, not yet on a physical panel, so it is offered only in a Gymza Custom set-up commissioned on a bench first.
Why does the turnstile not open when the reception PC is off?
Because Gymza keeps the panel empty of cards so that every rule stays in Gymza. Put the PC and the C3 on the same UPS, or keep a separate card list in the panel with ZKAccess as a fallback.
Which turnstile goes with a C3-200?
Any turnstile with a dry-contact input per direction can be wired to it. ZKTeco recommends the C3-200 Pro Plus for its TS2000 Plus, the turnstile of Gymza’s reference kit.
Sources
Documents read for this page, with the date they were read. Gymza evidence is the application and its test records (not public).
- Manufacturer · C3 Plus Series, product page (opens in a new tab) · ZKTeco · accessed
- Manufacturer · TS2000 Plus Series, product page (opens in a new tab) · ZKTeco · accessed
- Gymza · Gymza application: turnstile commissioning guide (INSTALL-TURNSTILE.md) and ZKTeco C3 adapter · Atlaxys Consulting · accessed
- Gymza · Gymza application: hardware documentation and RFID input code (HARDWARE.md, card-number.ts, rfid-input.ts) · Atlaxys Consulting · accessed