Skip to main content
Gymza

Access controllers

ZKTeco C3-100: a one-door controller for a gym entrance

The ZKTeco C3-100 is a networked access-control panel for one door: two Wiegand reader ports, one lock relay, one auxiliary relay. With Gymza it can release a turnstile or a door for members who are allowed in. It controls one direction only. For a turnstile that must also be controlled on the way out, use the C3-200.

Implemented, validation pendingPage reviewed on: , based on Gymza 1.3.1

In short

  • One door, 2 Wiegand readers (W26/W34/W66), 1 lock relay + 1 auxiliary relay, TCP/IP and RS-485 (ZKTeco’s C3 Plus specifications).
  • Gymza talks to it over the network (TCP 4370): it reads the badge events and pulses the door 1 lock relay when the rules allow entry.
  • Gymza never drives the auxiliary relay, so the C3-100 gives one controlled direction, typically entry, with a free-wheeling exit.
  • Status: implemented, validation pending: built from ZKTeco’s published protocol and tested against a simulator, not yet on a physical panel.

What works with Gymza

Function by function: status and evidence
FunctionStatusEvidence or limit
Connection, model and firmwareImplemented, validation pendingImplemented: session handshake on TCP 4370; the device log shows a line such as “CONNECTED C3-100 …” with the panel’s own model and firmware.
Badge reads in real timeImplemented, validation pendingImplemented: the panel holds none of Gymza’s cards, so every badge is logged as “unregistered”; Gymza polls that log several times a second.
Opening the door (lock relay, door 1)Implemented, validation pendingImplemented: Gymza asks the panel to pulse the relay for the configured time (4 s by default). Validated byte for byte against a simulator only.
Controlled exit (second direction)Not supportedNot supported on a C3-100: the second direction would need a second lock relay. Gymza does not drive the auxiliary relay.
Opening when the PC is offNot supportedNot supported with Gymza alone: the panel holds no cards, so it cannot decide. Cards loaded with ZKAccess form a separate list Gymza never touches.
Automatic detection on the local networkImplemented, validation pendingImplemented (Gymza 1.3.5): Gymza finds the controller on the PC’s local network and reads only its model, firmware and serial number, with no password and no relay. Nothing is saved without the administrator; a new address is recognised by the serial number. C3 driver experimental.
FingerprintsNot supportedNot supported: a classic C3 stores and matches no fingerprints, and its protocol has no biometric command. With readers such as the KR901, this hardware works with badges only. For fingerprints: a ZKTeco controller that stores and matches fingerprints itself, enrolled from a ZK8500R USB reader at reception (Gymza 1.4.0, experimental).

Specifications

Manufacturer values are taken from its documentation; values marked “Gymza” come from the application or our tests.

Checked specifications and the document they come from
SpecificationValueSource
Doors1[1] Manufacturer
Wiegand readers2 (W26 / W34 / W66)[1] Manufacturer
RS-485 readers2 (ZKTeco RS-485 / OSDP)[1] Manufacturer
Relays1 lock relay + 1 auxiliary (Form C)[1] Manufacturer
Inputs1 exit button, 1 door sensor, 1 auxiliary input[1] Manufacturer
NetworkTCP/IP ×1, RS-485 ×1[1] Manufacturer
Capacity100,000 cards, 500,000 transactions[1] Manufacturer
Power supply9.6–14.4 V DC[1] Manufacturer
Operating temperature0 °C … 45 °C[1] Manufacturer
Dimensions (L × W × H)175 × 99 × 19.3 mm[1] Manufacturer
How Gymza uses itGymza drives the door-1 lock relay; never the auxiliary relay[2] Gymza

What the C3-100 is

The C3 family is ZKTeco’s line of networked access panels: C3-100 (one door), C3-200 (two) and C3-400 (four), in several generations (Pro, Plus, Pro Plus). On its C3 Plus series page, ZKTeco lists for the C3-100 Plus: 1 access point, 2 Wiegand reader ports (26/34/66-bit), 2 RS-485/OSDP readers, Form C relays for 1 lock + 1 auxiliary, one exit-button input, one door-sensor input, one auxiliary input, a TCP/IP port, a 9.6–14.4 V DC supply and an operating range of 0–45 °C.

On its own, a C3 is a complete access controller: it stores up to 100,000 cards and decides by itself. Gymza deliberately uses it differently.

How Gymza uses it: the panel opens, Gymza decides

  1. 1BadgeThe member shows a card, key fob or wristband.
  2. 2ReaderIt reads the number and sends it to the controller, usually over Wiegand.
  3. 3ControllerIt passes the read to the PC over the network cable.
  4. 4GymzaMembership, hours, unpaid balance, anti-passback: the software decides.
  5. 5RelayThe controller closes the contact for a few seconds.
  6. 6TurnstileThe arm releases and the entry is recorded.

The software decides (4)

The controller opens (5–6)

Diagram. From badge to turnstile: the reader reads, the C3 reports, Gymza decides, the C3’s relay opens.

Gymza leaves the panel holding none of its cards. Every badge is therefore an “unregistered card” to the C3, which writes it in its real-time log. Gymza reads that log within a fraction of a second, applies the gym’s rules (membership, opening hours, unpaid balance, anti-passback, daily limit) and, if the answer is yes, asks the C3 to pulse the lock relay of door 1.

This keeps every rule in one place. It also has a consequence you must plan for: with the panel empty, a PC that is off means a door that does not open. Put the PC and the controller on the same UPS.

One door, one controlled direction

A tripod turnstile has one input per direction. To release the entry, Gymza closes the lock relay of door 1. To also control the exit, it needs a second door (a second lock relay), which the C3-100 does not have. ZKTeco’s C3-100 can take two readers on its one door (in and out), but both would open the same relay.

C3-100 or C3-200 for a gym turnstile
NeedC3-100C3-200
Controlled entry, free exitYes (door 1)Yes (door 1)
Controlled entry and exit (anti-passback that knows who left)NoYes (door 1 = In, door 2 = Out)
Two separate entrancesNoYes, one door each

The full comparison is in C3-100 or C3-200.

Installation and configuration

  1. Wiring: Wiegand reader on reader port 1 (D0/D1, its own 12 V and ground); turnstile entry input on LOCK1 NO/COM (dry contact); a ground shared between controller and turnstile.
  2. Power: the controller on its own 12 V supply, not shared with the turnstile motor.
  3. Network: a fixed IP on the same subnet as the reception PC, no router hop, no Wi-Fi bridge. Check port 4370 from the PC.
  4. In Gymza: Hardware → Add a device → access controller, adapter zkteco.c3, the IP, port 4370, door 1, direction In, and the communication password: leave it empty, most panels have none; if one was set, it is the one in ZKAccess.
  5. Bench test before fixing the turnstile: test pulse, valid card, lapsed card, cable unplugged and replugged.

Gymza’s commissioning checklist for this family is written for the C3-200; for a C3-100, skip the second door. See connecting a turnstile and dry-contact relays.

Common mistakes

  • Leaving ZKAccess or ZKBio connected to the panel: two masters on one C3 means events neither sees reliably.
  • Buying a C3-100 for a turnstile that must be controlled in both directions.
  • No shared ground between the C3 and the turnstile: the relay pulse is seen intermittently.
  • Expecting the turnstile to open with the PC off while the panel holds no cards.

Troubleshooting

C3 controller: messages and fixes
What you seeMeaningWhat to do
Device red, “no answer”Wrong IP or port, or panel offPing the IP, test port 4370 from the PC
“The communication password is not correct”The password entered does not match the panel’sEnter the one set in ZKAccess, or clear the field if the panel has none
“The panel refused the command”Before Gymza 1.3.6, a panel with no communication password could be refused, even though it worked with ZKAccessUpdate Gymza to version 1.3.7 or later, close ZKAccess, leave the password empty unless one was set in ZKAccess
“Connection closed”Another program holds the panel’s connection; or, before Gymza 1.3.7, a panel that works without a session (some C3-200)Close ZKAccess or ZKBioSecurity on every PC, including the icon next to the clock; if the panel works with ZKAccess, update Gymza to version 1.3.7 or later
Card read, turnstile does not moveWiring or entrance bindingUse Test: a relay click means wiring is fine
Some cards unknown at the doorReader number formatSee RFID troubleshooting

Frequently asked questions

Does Gymza work with the ZKTeco C3-100?

Gymza implements the C3 network protocol and drives door 1, but this has not yet been validated on a physical panel. It is offered only in a Gymza Custom configuration, commissioned on a bench by ATLAXYS first.

Can a C3-100 control both directions of a turnstile?

Not with Gymza. Gymza drives one lock relay per door, and the C3-100 has one door. For a controlled entry and exit, use a C3-200 (door 1 In, door 2 Out).

Do I need ZKAccess or ZKBio software?

No. Gymza speaks the panel’s protocol directly. If an installer uses ZKAccess on the same panel, it must be disconnected while Gymza is running.

Sources

Documents read for this page, with the date they were read. Gymza evidence is the application and its test records (not public).

  1. Manufacturer · C3 Plus Series, product page (opens in a new tab) · ZKTeco · accessed
  2. Gymza · Gymza application: turnstile commissioning guide (INSTALL-TURNSTILE.md) and ZKTeco C3 adapter · Atlaxys Consulting · accessed
  3. Gymza · Gymza application: hardware documentation and RFID input code (HARDWARE.md, card-number.ts, rfid-input.ts) · Atlaxys Consulting · accessed

A turnstile or door with a C3?

Turnstile installations are quoted as Gymza Custom. Tell us the panel model and firmware, and what you want to control.

Download Gymza